+86 13012999975

The YT-UM series rack-mount modular UPS can be installed as a standalone tower unit or is also suitable for standard 19-inch network cabinets. Employing online double-conversion technology, it completely eliminates various power grid problems and provides customers with stable, pure sinusoidal power protection.
This product has a wide range of applications, providing safe, stable, reliable, and environmentally friendly power supply for critical loads in various industries such as telecommunications, finance, education, transportation, broadcasting, healthcare, and manufacturing.
Ultra-wide input voltage range, adaptable to harsh power grid environments.
Wide input frequency range, compatible with fuel generators.
Overall efficiency greater than or equal to 95%.
Input power factor up to 0.99, input harmonic current less than 3%6.
Strong load-carrying capacity, highly adaptable to various loads.
Suitable for standard network cabinets and integrated power distribution cabinets, forming backup power supply systems.
4.3/7-inch color touchscreen, easy to operate and maintain.
Intelligent management functions, supporting RS485, SNMP, dry contact, and CAN interfaces.
| Parameter | Category | Value |
|---|---|---|
| Input | Capacity | 10-200kVA |
| Wiring System | 3-Phase 5-Wire | |
| Rated Input Voltage | 380/400/415Vac | |
| Input Voltage Range | 138~485Vac | |
| Input Frequency Range | 40Hz-70Hz | |
| Input Power Factor | ≥0.99 | |
| Input Current THDi | ≤3% (100% linear load) | |
| Bypass Voltage Range | 220Vac upper limit: 25% (+10%, +15%, +20% optional) 230Vac upper limit: 20% (+10%, +15% optional) 240Vac upper limit: 15% (+10% optional) Lower limit: -45% (-10%, -20%, -30% optional) | |
| Generator Connection | Supported | |
| Output | Wiring System | 3-Phase 5-Wire |
| Rated Output Voltage | 380/400/415Vac | |
| Output Power Factor | 0.9 or 1 | |
| Voltage Accuracy | ±1% | |
| Voltage Regulation (Mains Mode) | ±1%, ±2%, ±4%, ±5%, ±10% adjustable | |
| Voltage Regulation (Battery Mode) | (50/60±0.1%)Hz | |
| Current Crest Ratio | 3:1 | |
| Output Voltage THDv | ≤2% (100% linear load); ≤4% (100% non-linear load) | |
| Overall Efficiency | 96% | |
| Overload Capacity | 110% load: transfer to bypass after 60min 125% load: transfer to bypass after 10min 150% load: transfer to bypass after 1min | |
| Battery | Battery Voltage | ±180V/192V/±204V/±216V/±228V/±240V/±252V/±264V/±276V/±288V/±300Vdc (30-50 cells optional) |
| Charging Current | 2 slots: 20A / 4 slots: 40A / 6 slots: 60A | |
| Module | Max 10A | |
| Function | Transfer Time | Mains to bypass: 0ms (tracking) Mains to battery: 0ms |
| Alarm Functions | Overload, mains abnormality, UPS fault, battery undervoltage, and more | |
| Protection Functions | Battery undervoltage, output over/under voltage, short circuit, overload, over temperature, fan fault alarm, surge protection | |
| Communication Interfaces | CAN, RS485, FE, LBS, parallel card, SNMP adapter (optional), relay card (optional) | |
| Environment | Operating Temperature | 0℃ ~ 40℃ |
| Storage Temperature | -25℃ ~ 55℃ | |
| Humidity Range | 0~95% (non-condensing) | |
| Operating Altitude | <1500m |
| Cabinet Capacity | 20/30kVA | 40/60kVA | 60/90/120/150kVA | |
|---|---|---|---|---|
| Max Number of Modules | 2 | 4 | 6 (30kVA module: 5+1 redundancy) | |
| Compatible Power Modules | 10/15kVA | 10/15kVA | 10/15/20/25/30kVA | |
| Rack/Tower Compatible Model Dimensions (mm) | 750×545×649 | 750×545×827 | 750×545×1005 | |
| Module Dimensions (mm) | 440×620×86 | |||
| Cabinet Weight (kg) | 63 | 75 | 87 | |
| Module Weight (kg) | 10/15/20kVA: 20.8; 25/30kVA: 21.6 |
| Cabinet Capacity | 40/50/60/100kVA | 80/100/120/200kVA | 120/150kVA | |
|---|---|---|---|---|
| Max Number of Modules | 2 | 4 | 6 (30kVA module: 5+1 redundancy) | |
| Compatible Power Modules | 20/25/30/50kVA | 20/25/30kVA | ||
| Cabinet Dimensions (mm) | 40/50/60kVA: 835×485×356 | 80/100/120kVA: 835×485×534 | 485×835×712 | |
| Rack-Mount Only Models (mm) | 100kVA: 485×825×489.5 | 200kVA: 485×835×756.5 | ||
| Module Dimensions (mm) | 20/25/30kVA: 620×440×86 | 50kVA: 440×620×131 | ||
| Cabinet Weight (kg) | 40/50/60kVA: 44.5 | 80/100/120kVA: 53.5 | 63.5 | |
| Module Weight (kg) | 20kVA: 20.8; 25/30kVA: 21.6; 50kVA: 33 |