+86 13012999975

Series 10-80kVA trium input tres output plene digitalis imperium online duplex conversio tres input tres output UPS lineamenta alta altiore efficientia, alta factor potentiae input, humilis input vena harmonica, et qualitas output optima. Potestas varias difficultates emissionis tollere ac clientes stabili ac certa potentia praesidii praebere.
Productum hoc amplis applicationibus habet, ut tuta, stabilis, certa, et amicabilis potentia copia subsidiorum criticorum in variis industriis, ut in telecommunicatione, oeconomicis, oeconomicis, educationibus, translationibus, emissionibus, curis, et fabricandis, praebeat.
Potentia dolor: 10-80kVA
Modus operating: Tres initus, tres outputs
Ultra-wide input range voltage, apta ad vim asperam eget ambitibus.
Lata input frequentia range, compatible cum cibus generantibus.
Sustinet directam altilium satus-sursum in absentia maioris potentiae.
Instructus cum EPO subitis shutdown interface.
Altiore efficientia ≥ 95.5%6
Input potentia factor usque ad 0.99, initus harmonica current <3%6
Fortis oneris ferens facultatem, variis oneribus valde accommodata, cum operatione generantis compatibilis.
Sustinet nexum parallelum de 4 unitatibus et communicantes machinam machinam.
Nullam suscipit tincidunt velit.
4.3-inch color touchscreen, facile ad operari.
Intelligentes functiones procurationes, subsidia RS485, SNMP, contactum siccum, et interfaces CAN.
| Categoria | Parameter | 3310 (10kVA) | 3320 (20kVA) | 3330 (30kVA) | 3340 (40kVA) | 3360 (60kVA) | 3380 (80kVA) |
|---|---|---|---|---|---|---|---|
| capacitas | |||||||
| capacitas | Rated Capacity (kVA) | 10 | 20 | 30 | 40 | 60 | 80 |
| Input | |||||||
| Input | Wiring System | 3-Phase 5-Wire | |||||
| Rated Input Voltage | 380/400/415Vac | ||||||
| Input intentione dolor | 138~485Vac | ||||||
| Input Frequency Range | 40Hz~70Hz | ||||||
| Input Power Factor | ≥0.99 | ||||||
| Input Current THDi | ≤3% (C% onere lineari) | ||||||
| Bypass intentione dolor | 220Vac superior: 25% (+10%, +15%, +20% opt); 230Vac superior: 20% (+10%, +15% opt); 240Vac superior: 15% (+10% opt); Inferior: -45% (-10%,-20%,-30% opt) | ||||||
| Generator Connection | Supported | ||||||
| Output | |||||||
| Output | Wiring System | 3-Phase 5-Wire | |||||
| Rated Output intentione | 380/400/415Vac | ||||||
| Output Power Factor | 0.9 | ||||||
| Voltage Accuracy | ±1% | ||||||
| Frequentia | Modus mains: ±1%/±2%/±4%/±5%/±10% commodabilis; Pugna modus: (50/60±0.1%)Hz | ||||||
| Current Crest Ratio | 3:1 | ||||||
| Output intentione THDv | ≤2% (100% onere lineari); ≤4% (C% non-linearibus onus) | ||||||
| Altiore Efficens | 95.5% | ||||||
| Overload Capacity | 110% onus: 60min → bypass; 125% onere: 10min → praeterire; 150% onus: 1min → bypass | ||||||
| Pugna | |||||||
| Pugna | Pugna intentione | ±180/192/±204/±216/±228/±240/±252/±264/±276/±288/±300Vdc (30-50 cellulae ad libitum) | |||||
| Mandantes Current (A) | 10 | 10 | 10 | 15 | 15 | 20 | |
| TRANSFERENDIS | |||||||
| TRANSFERENDIS | Transfer Tempus | Mains to bypass: 0ms (track); Mains in altilium: 0ms | |||||
| Environment | |||||||
| Environment | Operating Temperature | 0°C ~ 40°C | |||||
| Repono Temperature | -25°C ~ 55°C | ||||||
| Umor dolor | 0~ XCV% (non-condensatione) | ||||||
| Altitude operating | <150m | ||||||
| Vox (dB ad 1m) | <55 | <55 | <55 | <58 | <58 | <60 | |
| Munera | |||||||
| Munera | Terror functiones | ONERO, mains deprauatio, UPS culpa, altilium undervoltage, etc. | |||||
| Praesidium functiones | Pugna undervoltage, output over/under intention, short circuit, over temp, fan culpa terror, impetus tutelae | ||||||
| Communication Interfaces | CAN, RS485, FE, LBS, card parallela, SNMP adaptor (opt), Nullam card (opt) | ||||||
| Corporalis | |||||||
| Corporalis | Dimensiones (D×W×H mm) | 710×250×535 | 880×280×880 | 885×440×1200 | |||
| Net Pondus (kg) | 32 | 36.4 | 39.4 | 41 | 68.2 | 150 | |
| Standard | |||||||
| Standard | Lorem Latin | YD/T 1095-2018 | |||||