+86 13012999975

Tsarin 200-600kVA na shigarwar matakai uku da fitarwa na uku-uku UPS sabon ƙarni ne na shigarwar juzu'i biyu na kan layi da fitarwa na UPS uku. Yana ɗaukar ƙirar ƙirar ƙirar ƙira, cikakken iko na dijital da fasaha na matakai uku, kuma yana da fa'idodi na babban inganci, babban ƙarfin ƙarfi da ingantaccen fitarwa. Zai iya kawar da matsalolin grid na wutar lantarki daban-daban kuma ya ba abokan ciniki kariya mai ƙarfi da aminci.
IDC (Cibiyar Bayanai ta Intanet) dakuna, manyan cibiyoyin bayanai manya da matsakaita, cibiyoyin kudi, manyan cibiyoyin bayanan kasuwanci, da sauransu.
Wurin wutar lantarki: 200-600 kVA
Yanayin aiki: Abubuwan shigarwa uku da fitarwa guda uku
138-485Vac matsananci-fadi na shigarwar ƙarfin lantarki da kewayon shigarwa mai faɗi, mai daidaitawa zuwa mahallin grid mai ƙarfi.
Ayyukan aiki tare na LBS yana ba da damar aiki tare na ƙungiyoyin UPS guda biyu, inganta amincin tsarin.
Ya karɓi ilimin topology mataki-mataki uku, yana samun ingantaccen aiki na gabaɗaya har zuwa 95.5%6.
Matsakaicin ƙarfin shigarwa har zuwa 0.99, shigar da jituwa ƙasa da 396.
Ƙarfin nauyi mai girma, mai iya ɗaukar nauyin nauyin 100% marasa daidaituwa, ƙarfin ɗaukar nauyi, kuma mai dacewa da janareta.
Yana goyan bayan raka'a 6 a layi daya da raba fakitin baturi, tare da zaɓaɓɓun sel baturi 30-50.
Yana goyan bayan gwajin tsufa mara kaya.
7-inch allon taɓawa mai launi tare da nunin hoto, mai sauƙin aiki.
Ayyukan gudanarwa na hankali, tallafawa RS485, SNMP, busassun lamba, da musaya na CAN.
| Kashi | Siga | 33200 (200kVA) | 33300 (300kVA) | 33400 (400kVA) | 33500 (500kVA) | 33600 (600kVA) |
|---|---|---|---|---|---|---|
| Iyawa | ||||||
| Iyawa | Ƙarfin Ƙarfi (kVA) | 200 | 300 | 400 | 500 | 600 |
| Shigarwa | ||||||
| Shigarwa | Tsarin Waya | 3-Mataki na 5-Waya | ||||
| Ƙimar Input Voltage (Vac) | 380/400/415 | |||||
| Input Voltage Range (Vac) | 138-485 | |||||
| Matsakaicin Shigarwa (Hz) | 40Hz-70 | |||||
| Factor Power Input | > 0.99 | |||||
| Shigar da THDi na yanzu | ≤3% (100% na layi na layi) | |||||
| Kewayon Wutar Lantarki | 220Vac babba: 25% (+ 10%, 15%, 20% ficewa); 230Vac babba: 20% (+ 10% + 15% ficewa); 240Vac babba: 15% (+ 10% fita); Ƙananan: -45% (-10%, -20%, -30% opt) | |||||
| Haɗin Generator | Tallafawa | |||||
| Fitowa | ||||||
| Fitowa | Tsarin Waya | 3-Mataki na 5-Waya | ||||
| Ƙimar Wutar Lantarki (Vac) | 380/400/415 | |||||
| Factor Power Factor | 0.9 | |||||
| Daidaiton Wutar Lantarki | ± 1% | |||||
| Mitar (Yanayin Babban) | ± 1% / ± 2% / 4% / ± 5% / ± 10% daidaitacce | |||||
| Mitar (Yanayin baturi) | (50/60 ± 0.1%) Hz | |||||
| Rabon Crest na yanzu | 3:1 | |||||
| Fitar da Wutar Lantarki THDv | ≤2% (100% lodi na layi); ≤4% (100% kaya mara nauyi) | |||||
| Gabaɗaya Inganci | 95.5% | |||||
| Ƙarfin Ƙarfafawa | 110% lodi: 60min → wucewa; 125% lodi: 10min → wucewa; 150% lodi: 1min → wucewa | |||||
| Baturi | ||||||
| Baturi | Wutar Batir | ± 180/192 / ± 204 / ± 216 / 228 / 240 / 252 / ± 264 / ± 276 / ± 288 / ± 300Vdc (30-50 sel na zaɓi) | ||||
| Ayyuka | ||||||
| Ayyuka | Lokacin Canja wurin | Mais don kewayawa: 0ms (bibiya); Matsakaicin baturi: 0ms | ||||
| Ayyukan Ƙararrawa | Matsakaicin nauyi, rashin daidaituwa na mains, kuskuren UPS, ƙarancin ƙarfin baturi, da sauransu. | |||||
| Ayyukan Kariya | Ƙarƙashin ƙarfin baturi, fitarwa sama da/ƙarƙashin ƙarfin lantarki, gajeriyar kewayawa, wuce gona da iri, sama da zafin jiki, ƙararrawar kuskuren fan, kariya mai ƙarfi | |||||
| Hanyoyin Sadarwa | CAN, RS485, FE, LBS, katin layi ɗaya, adaftar SNMP (ficewa), katin gudun hijira (ficewa) | |||||
| Muhalli | ||||||
| Muhalli | Yanayin Aiki | 0°C ~ 40°C | ||||
| Ajiya Zazzabi | -25°C ~ 55°C | |||||
| Rage Danshi | 0 ~ 95% (ba mai tauri) | |||||
| Tsayin aiki (m) | <1500 | |||||
| Amo (dB a 1m) | <65 | <68 | <70 | <70 | <70 | |
| Na zahiri | ||||||
| Na zahiri | Girma (D×W×H mm) | 850×600×2000 | 850×1200×2000 | |||
| Net Weight (kg) | 335 | 400 | 638 | 740 | 843 | |
| Daidaitawa | ||||||
| Daidaitawa | Ma'auni mai dacewa | YD/T 1095-2018 | ||||