UPS yuav khaws cov cuab yeej ua haujlwm ntev npaum li cas thaum muaj hluav taws xob? Cov lus teb nyob ntawm ntau dua li VA tus lej luam tawm ntawm lub vaj huam sib luag pem hauv ntej. UPS lub sijhawm ua haujlwm yog txiav txim siab los ntawm kev sib txuas tiag tiag, roj teeb lub zog, kev ua haujlwm ntawm inverter, lub peev xwm siv tau, roj teeb thiab kev ua haujlwm kub.
Teb ceev: Qhov kev kwv yees kwv yees kwv yees yog:
Runtime (teev) ≈ Roj teeb-bank voltage × amp-teev × parallel hlua × efficiency × usable-capacity factor ÷ txuas load hauv watts
Cov mis no muaj txiaj ntsig zoo rau kev loj hlob thaum ntxov, tab sis nws tsis yog lub sijhawm lav. Lead-acid paug tus cwj pwm tsis yog-linear, thiab cov tshuab tiag tiag kuj muaj kev txwv txiav tawm ntawm inverter, roj teeb aging, cable poob thiab qhov kub thiab txias. Kev xaiv zaum kawg yuav tsum siv UPS cov chaw tsim khoom lub sijhawm ua haujlwm cov ntaub ntawv thiab kev suav cov roj teeb tshwj xeeb.
Ua ntej xam UPS roj teeb lub sijhawm, sau cov nqi no:
Yog tias ib qho ntawm cov txiaj ntsig no ploj lawm, qhov tshwm sim tuaj yeem ua rau yuam kev.
Ntau UPS sizing yuam kev pib los ntawm kev kho VA, watts thiab watt-teev raws li kev hloov pauv.
| Chav tsev | Qhov nws piav | Yuav siv li cas |
|---|---|---|
| VA or kVA | Pom muaj zog muaj peev xwm | Paub meej tias UPS tuaj yeem txhawb nqa qhov kev thov tam sim no |
| W lub kW | Lub zog tiag tiag siv los ntawm kev thauj khoom | Siv los xyuas UPS watt muaj peev xwm thiab kwv yees lub sijhawm ua haujlwm |
| Ah | Roj teeb muaj peev xwm | Yuav tsum tau ua ke nrog roj teeb voltage los kwv yees lub zog khaws cia |
| Wh or kWh | Hluav taws xob | Siv los ua qhov chaw pib rau kev suav sijhawm |
Qhov kev sib raug zoo ntawm watts thiab VA yog:
Watts = VA × Power Factor
Yog li ntawd:
Yuav tsum muaj VA = Load Watts ÷ Fais Fab Factor
Piv txwv li: yog tias cov cuab yeej siv 1,800 W thiab lub zog siv tau yog 0.9:
1,800 W ÷ 0.9 = 2,000 VA
UPS yuav tsum txhawb nqa tsawg kawg yog 1,800 W thiab 2,000 VA. Tom qab ntawd daim phiaj xwm phiaj xwm thiab kev loj hlob yav tom ntej yuav tsum tau ntxiv ua ntej xaiv tus qauv kawg.
Rau ib txoj hlua roj teeb:
Nominal roj teeb lub zog (Wh) = DC tsheb npav voltage × roj teeb Ah
Yog hais tias cov hlua zoo tib yam txuas nrog rau hauv parallel:
Nominal roj teeb lub zog (Wh) = DC tsheb npav voltage × Ah × tus lej ntawm cov hlua sib txuas
Hauv ib txoj hlua, roj teeb voltages ntxiv tab sis qhov ntsuas Ah tsis ua. Hauv cov hlua sib txuas, Ah muaj peev xwm ntxiv thaum txoj hlua hluav taws xob tseem zoo li qub.
Lub inverter thiab sab hauv UPS Cheebtsam siv lub zog. Kev npaj kev suav yuav siv qhov ua tau zoo xws li 0.85 txog 0.95, nyob ntawm qhov system thiab thauj khoom.
Zog tom qab hloov dua siab tshiab poob = Nominal Wh × UPS efficiency
Siv cov ntaub ntawv tsim khoom tiag tiag thaum muaj.
Lub roj teeb yuav tsum tsis txhob raug kho zoo li yog 100% ntawm nws lub npe lub zog yuav mus txog qhov load. Siv cov yam ntxwv rau:
Rau kev npaj ua ntej, cov no tuaj yeem muab tso ua ke rau hauv kev siv tau-muaj peev xwm. Tus nqi raug yuav tsum yog los ntawm lub roj teeb thiab UPS tsim cov cai.
Runtime (teev) = Usable roj teeb lub zog (Wh) ÷ Load (W)
Muab 60 rau feeb:
Runtime (feeb) = Runtime (teev) × 60
Xav tias:
Nominal zog:
48 V × 100 Ah = 4,800 Wh
Kwv yees siv zog:
4,800 x 0.90 x 0.70 = 3,024 Wh
Planning runtime:
3,024 Wh ÷ 800 W = 3.78 teev, lossis kwv yees li 227 feeb
Qhov no yog qhov yooj yim zog kwv yees. Lub sijhawm ua haujlwm tiag tiag tuaj yeem luv dua vim tias cov kua qaub muaj peev xwm hloov pauv nrog tus nqi tso tawm, lub hnub nyoog roj teeb thiab kev txiav tawm hluav taws xob. Lub chaw tsim khoom lag luam yuav tsum tau ua haujlwm ua ntej cog lus 227 feeb rau tus neeg siv kawg.
Xav tias:
Nominal zog:
384 V × 100 Ah = 38,400 Wh
Kwv yees siv zog:
38,400 x 0.92 x 0.70 = 24,729.6 TZS
Planning runtime:
24,729.6 Wh ÷ 10,000 W = 2.47 teev, lossis kwv yees li 148 feeb
Qhov piv txwv no qhia tau hais tias tus qauv ua haujlwm li cas, tsis yog kev tsim qauv thoob ntiaj teb. Lub roj teeb kom muaj nuj nqis, DC voltage thiab lub peev xwm them nyiaj yuav tsum ua raws li UPS xaiv. High-voltage roj teeb systems xav tau kev engineering, kev tiv thaiv cov cuab yeej thiab cov txheej txheem kev nyab xeeb.
Ib qho zoo tagnrho xam faib nominal watt-teev los ntawm load watts. Lub sijhawm roj teeb tiag tiag tau cuam tshuam los ntawm cov xwm txheej ntxiv.
Lead-acid roj teeb xa cov peev xwm siv tsawg dua ntawm cov pa tawm siab dua li qhov yooj yim Ah xam yuav qhia. Qhov kev coj cwj pwm no yog ib qho laj thawj uas lub sijhawm ua haujlwm tsis hloov pauv hauv txoj hauv kev zoo kawg nkaus nrog kev thauj khoom.
Lub roj teeb muaj peev xwm poob qis thaum lub sijhawm. Lub kaw lus loj tsuas yog rau kev ua haujlwm ntawm lub roj teeb tshiab tuaj yeem ua tsis tau raws li qhov yuav tsum tau ua nyob ze rau qhov kawg ntawm lub sijhawm hloov pauv.
Qhov kub qis tuaj yeem txo qhov muaj peev xwm. Qhov kub thiab txias yuav ua rau kom cov zis tawm ib ntus tab sis ua kom lub roj teeb muaj zog. Chav roj teeb yuav tsum nyob twj ywm nyob rau hauv qhov kev ua haujlwm tau pom zoo.
Lub inverter nres tawm ua ntej lub theoretical roj teeb lub zog mus txog xoom. Qhov no tiv thaiv lub roj teeb thiab tswj qhov system tswj.
Servers, cua txias kiv cua, motors thiab industrial cov khoom tsis tas yuav kos lub zog tas li. Pib tam sim no thiab load peaks yuav tsum muaj nyob rau hauv tus tsim.
Tom qab xam qhov kev sib txuas load, ntxiv peev xwm rau kev khiav hauj lwm margin thiab xav kom loj hlob. Ib qho kev pib siv feem ntau yog kwv yees li 20-25% siab dua qhov kev thauj khoom tam sim no, tab sis cov paj tsim nyog nyob ntawm daim ntawv thov.
Zam ob qho tib si siab:
Rau kev teeb tsa modular, muaj peev xwm nthuav dav hauv theem. USYTU cov YT-UM khib-Modular UPS 10-200kVA txhawb modular configurations rau loj hlob tseem ceeb loads.
| Lub hom phiaj ntawm kev thov | Yam zoo runtime | Cov lus nug los teb |
|---|---|---|
| Orderly kaw lub computer | Lub sijhawm luv luv | Ntev npaum li cas software yuav tsum kaw kom zoo? |
| Network txuas ntxiv | Tswj cov routers thiab keyboards | Kev siv hluav taws xob hauv zos ib txwm nyob ntev npaum li cas? |
| Generator pib choj | Txhawb nqa kom txog thaum lub tshuab hluav taws xob stabilizes | Dab tsi yog qhov phem tshaj lub tshuab hluav taws xob pib thiab hloov lub sijhawm? |
| Server-room continuity | Extended runtime los yog generator choj | Cov loads twg yog qhov tseem ceeb, thiab yog qhov zoo nkauj kaw automated? |
| Kev tiv thaiv txheej txheem kev lag luam | Tswj tswj lossis ua kom tiav qhov chaw nyab xeeb | Lub sijhawm ua haujlwm dab tsi yuav tsum tau mus txog rau lub xeev txheej txheem kev nyab xeeb? |
| Data-center muaj nyob | Roj teeb choj ntxiv rau redundancy | Puas yog N + 1 muaj peev xwm, sib npaug UPS lossis kev saib xyuas kev hla dhau? |
Lub sijhawm ua haujlwm yuav tsum yog raws li lub hom phiaj ua haujlwm. "Raws li qhov ua tau" tsis yog qhov yuav tsum tau ua tiav engineering.
Kev xaiv roj teeb yuav tsum phim UPS them qhov system, DC voltage, tso tawm tam sim no thiab ib puag ncig kev teeb tsa.
USYTU muab ib roj teeb khoom qeb nrog ntau yam 12 V cia- roj teeb muaj peev xwm. Cov neeg yuav khoom ntsuas ncua-runtime systems tuaj yeem tshuaj xyuas cov 12V 100Ah cia roj teeb thiab 12V 200Ah cia roj teeb raws li cov khoom siv.
Tsis txhob xaiv lub roj teeb los ntawm Ah ib leeg. Paub meej:
Kev sib xyaw roj teeb ntawm cov hnub nyoog sib txawv, muaj peev xwm lossis cov xwm txheej hauv ib txoj hlua tuaj yeem txo kev ntseeg tau.
Sau txhua lub cuab yeej, nws qhov ntsuas watts, VA lossis lub zog muaj zog, pib tus cwj pwm thiab qhov tseem ceeb. Tshem cov khoom siv uas tsis xav tau roj teeb thaub qab.
Ntxiv lub zog tiag tiag hauv watts thiab lub zog pom tseeb hauv VA. Cov xaiv UPS yuav tsum txaus siab rau ob qho kev ntsuas.
suav nrog lub hauv paus kev ua haujlwm tsim nyog thiab paub txog kev nthuav dav yav tom ntej.
Qhia txog lub sijhawm ua haujlwm ntawm qhov kev cia siab - tsis yog ntawm qhov feem pua ntawm cov ntawv luam tawm hauv daim ntawv qhia.
Rau rhiab heev, lub hom phiaj tseem ceeb lossis daim phiaj tsis zoo, ib qho online UPS system tuaj yeem muab kev hloov pauv ob zaug txuas ntxiv lub zog txias thiab xoom lub sijhawm hloov mus rau roj teeb.
Txheeb xyuas qhov xav tau ntawm lub zog ua ntej, tom qab ntawd txheeb xyuas nws siv UPS xaiv thiab cov ntaub ntawv tso tawm roj teeb.
Xws li cov kev npaj bypass, breakers, cables, roj teeb racks, qhov cua, saib xyuas, kev ntsuam xyuas raws sij hawm thiab hloov roj teeb.
Muab cov ntaub ntawv hauv qab no kom tau txais cov lus pom zoo:
| RFQ teb | Cov ntaub ntawv muab |
|---|---|
| Daim ntawv thov | Chav tsev neeg rau zaub mov, cov ntaub ntawv chaw, kev kho mob, telecom, industrial lossis lwm yam |
| Cov cuab yeej tseem ceeb | Cov npe ntaus ntawv thiab kev ua haujlwm ua haujlwm |
| Tag nrho cov load | Watts thiab VA |
| Input mov | Voltage, theem thiab zaus |
| Yuav tsum tau tso zis | Voltage, theem thiab zaus |
| Runtime phiaj | feeb los yog teev ntawm qhov teev tseg |
| UPS topology | Online dual hloov dua siab tshiab los yog lwm yam |
| Rov qab | Tsis muaj, N + 1, sib npaug lossis ob lub npav |
| Roj teeb nyiam | VRLA, lithium-ion lossis qhov project tshwj xeeb |
| Ib puag ncig | Kub, av noo, qhov siab thiab plua plav |
| Lub tshuab hluav taws xob | Muaj peev xwm thiab voltage / zaus ntau yam |
| Saib xyuas | SNMP, RS485, hu qhuav lossis lwm yam |
| Kev npaj loj hlob | Cia siab tias yuav thauj khoom tom qab ib mus rau tsib xyoos |
Tsis yog. VA piav qhia meej lub zog muaj peev xwm, tsis khaws lub zog. Runtime xam yuav tsum tau lub load tiag tiag nyob rau hauv watts thiab cov ntaub ntawv hais txog lub roj teeb system.
Raws li cov xwm txheej zoo ib yam, ob npaug ntawm cov roj teeb uas siv tau tuaj yeem kwv yees li ob lub sijhawm ua haujlwm. Hauv kev xyaum, tus nqi tso tawm, UPS them cov nqi txwv, kev teeb tsa roj teeb thiab qhov system poob yuav tsum raug kuaj xyuas.
Tsis yog. Qhov ntsuas fais fab loj dua txhais tau tias UPS tuaj yeem txhawb nqa lub nra loj dua. Lub sijhawm ua haujlwm feem ntau nyob ntawm lub roj teeb lub zog thiab kev sib txuas ntawm kev thauj khoom. Ob lub tshuab UPS nrog tib qhov kev ntsuas kVA tuaj yeem muaj sijhawm sib txawv heev.
Nws tsis tuaj yeem txiav txim siab los ntawm Ah ib leeg. Roj teeb voltage, pes tsawg lub roj teeb, load watts, UPS efficiency, paug tus nqi thiab txiav tawm voltage kuj yuav tsum tau.
Cov ntaub ntawv chaw tsim khoom tuaj yeem suav rau cov roj teeb tawm tiag tiag, kev coj tus cwj pwm inverter thiab kev txwv txiav. Ib qho qauv yooj yim tsuas yog kev kwv yees kwv yees xwb.
Kev ua haujlwm yuav tsum txheeb xyuas UPS, tswb, hla dhau, roj teeb thiab saib xyuas. Txhua qhov kev tswj xyuas lub sijhawm yuav tsum ua raws li cov chaw tsim khoom cov lus qhia vim tias qhov tso tawm tag nrho tuaj yeem tawm ntawm qhov tseem ceeb ib ntus yam tsis muaj roj teeb txaus.
Txhawm rau kwv yees UPS lub sijhawm ua haujlwm, hloov lub txhab nyiaj roj teeb rau hauv lub sijhawm siv tau watt-teev thiab faib los ntawm qhov sib txuas tiag tiag. Tom qab ntawd kho qhov tshwm sim raws li tus nqi npaj-tsis yog qhov lav. Lub sijhawm ua haujlwm kawg yuav tsum raug txheeb xyuas tawm tsam UPS xaiv, cov ntaub ntawv tso tawm roj teeb, qhov kev txwv txiav tawm thiab qhov chaw nyob.
Rau kev xam txiav txim siab, xa qhov tseem ceeb-load watts thiab VA, xav tau lub sijhawm ua haujlwm, lub zog tawm tswv yim / tso zis, rov ua dua lub hom phiaj thiab ib puag ncig kev teeb tsa. Hu rau USYTU rau UPS thiab kev txhawb nqa roj teeb.