+86 13012999975

The UTE single-input single-output rack-mount UPS is a new generation of general-purpose UPS designed and manufactured by Shandong Fuhong Xunfei Electronic Technology Co., Ltd. It is compatible with tower or rack-mount installations and adopts an online, double-conversion architecture design. Compared with online interactive or standby UPS models, it provides a better power environment for user loads.
The product is widely applicable to Class I load equipment in government, finance, education, and SMEs.
Power range: 1-3kVA
Operating mode: Single input, single output
Network room and intelligent server rack solutions for enterprises, shopping malls, government agencies, finance, healthcare, education and other fields.
• Online double-conversion design, compatible with tower and rack mounting
• LCD display for easy operation and maintenance
• Wide input voltage (110Vac to 300Vac), adaptable to suboptimal power grid environments
• Input power factor ≥ 0.99, green power supply design
• Output power factor 1, strong load capacity
• Action mode efficiency up to 94%+, highly energy-efficient
• Long-life models with charging current up to 12A, multi-stage intelligent charging management
• Comprehensive protection mechanisms including undervoltage, overvoltage, short circuit, and overtemperature protection
• Standard RS232 interface, optional SNMP card and USB port
Compatible with tower or rack mounting, easily adapting to different installation environments.
Adopting an online double-conversion architecture and digital control technology, the pure sine wave output can power various types of loads, providing optimal power protection for users' load equipment.
When the mains power fails and is restored, the UPS switches between mains mode and battery mode with zero time, effectively ensuring the reliability of load operation. Factory-Green Power Design
Features input power factor correction, achieving an input power factor of 0.99 or higher, reducing pollution to the power grid and meeting the design principles of green power supplies.
When mains power is interrupted and then restored, the UPS automatically starts up, eliminating the need for manual restart and enabling unattended operation.
Utilizes multi-stage battery charging management technology, providing powerful charging capabilities and supporting large-capacity battery packs.
With a wide input voltage and frequency range, the UT11 series can be used with branded generators to provide clean, safe, and stable power to the load.
| Category | Parameter | YT-UR11 / 1101S | 1101 | 1102S | 1102 | 1103S | 1103 |
|---|---|---|---|---|---|---|---|
| Capacity/Power | 1kVA/1kW | 2kVA/2kW | 3kVA/3kW | ||||
| Input | Input Wiring System | L+N+PE | |||||
| Rated Input Voltage | 208/220/230/240Vac | ||||||
| Voltage Range | 110~300Vac | ||||||
| Frequency Range | 44~56Hz or 54~66Hz (default) | ||||||
| Input Power Factor | ≥0.99 | ||||||
| Output | Output Wiring System | L+N+PE | |||||
| Output Voltage | 208/220/230/240Vac | ||||||
| Output Voltage Accuracy | ±1% | ||||||
| Output Frequency | Online mode: follow mains frequency; Battery mode: 50/60Hz ±0.1% | ||||||
| Output THDv | ≤4% (linear load) | ≤5% (non-linear load PF=0.8) | |||||
| Output Power Factor | 1 | ||||||
| Transfer Time | Mains to battery: 0ms; Inverter to bypass: 4ms | ||||||
| Overload Capacity (Mains Mode) | 30min@102%~110%; 10min@110%~130%; 30s@130%~150%; 200ms@>150% | ||||||
| Overload Capacity (Battery Mode) | 1min@102%~110%; 10s@110%~130%; 3s@130%~150%; 200ms@>150% | ||||||
| Efficiency (Mains Mode) | 94.5% | 95.5% | 95.5% | ||||
| Battery | Battery Voltage | 2×12V 7/9Ah (internal) | 36Vdc | 4×12V 7/9Ah (internal) | 72Vdc | 6×12V 7/9Ah (internal) | 96Vdc |
| Charging Current | 1A | 1-12A(max) | 1A | 1-12A(max) | 1A | 1-12A(max) | |
| Display | Display Interface | LCD, supports operation mode/load/battery/input/output | |||||
| Communication | Communication Interfaces | Standard RS232, optional SNMP card, USB | |||||
| Environment | Operating Temperature | 0~40°C | |||||
| Operating Humidity | 20%~95% (non-condensing) | ||||||
| Altitude | <1000m (derate above 1000m, max 4000m per IEC62040) | ||||||
| Dimensions | W×D×H (mm) | 438×315×86.8 | 438×400×86.8 | 438×400×86.8 | 438×500×86.8 | ||
| Weight | Net Weight (kg) | 9.8/10.8 | 4.8 | 16.4/18.4 | 8 | 21/24 | 8.2 |
| Category | Parameter | YT-UR1106 | YT-UR1110 |
|---|---|---|---|
| Capacity/Power | 6kVA/6kW | 10kVA/10kW | |
| Input | Input Wiring System | L+N+PE | |
| Rated Input Voltage | 208/220/230/240Vac | ||
| Voltage Range | 110~300Vac | ||
| Frequency Range | 44~56Hz or 54~66Hz | ||
| Input Power Factor | ≥0.99 | ||
| Output | Output Wiring System | L+N+PE | |
| Output Voltage | 208/220/230/240Vac | ||
| Output Voltage Accuracy | ±1% | ||
| Output Frequency | Online mode: follow mains frequency; Battery mode: 50/60Hz ±0.1% | ||
| Output THDv | ≤2% (linear load); ≤5% (non-linear load) | ||
| Output Power Factor | 1 | ||
| Transfer Time | 0ms | ||
| Overload Capacity (Mains Mode) | 30min@102%~110%; 10min@110%~130%; 30s@130%~150%; 200ms@>150% | ||
| Overload Capacity (Battery Mode) | 10min@102%~110%; 1min@110%~130%; 10s@130%~150%; 200ms@>150% | ||
| Efficiency (Mains Mode) | 95% | ||
| Battery | Battery Voltage | 192~240Vdc | |
| Charging Current | 1-12A(max) | ||
| Display | Display Interface | LCD, supports operation mode/load/battery/input/output | |
| Communication | Communication Interfaces | Standard RS232, EPO, optional SNMP card, USB | |
| Environment | Operating Temperature | 0~40°C | |
| Operating Humidity | 20%~95% (non-condensing) | ||
| Altitude | <1000m (derate above 1000m, max 4000m per IEC62040) | ||
| Dimensions | W×D×H (mm) | 438×500×86.8 | |
| Weight | Net Weight (kg) | 8.8 | 11 |